Public utilities including sewer, water, electrical, gas, phones and internet.
Electrical consists of three phase power at 440 voltage.
The whole facility is wired for Ethernet network and air lines.
The compressor is housed in a seperate room with a Palateck 25D4D compressor (25 horsepower), a Sullair 10B-25&30HP compressor (25 horsepower), and a Palateck PRDA200 dryer (50 wattage).
2 alarm systems for the entire site. 1 is for the office and 1 is for the shop.
New building CO was 3rd quarter of 2002 and offers the following:
40,500 sq. ft. (300' x 155' )
1900 sq. ft. office/bathroom space with central heat and air (excluded office below)
90' x 70' fenced area for storage with 600 foot office
Gas heat for production floor
Updraft ceiling fans and wall louvers for ventilation
Ceilings are 16' at minimum and 20' at maximum
Incandescent lighting with a few florescent lights
3 dock high roll up doors
5 ground high roll up doors
1 ramp roll up door
6 man door exits
Reinforced concrete foundation extended below frost line with steel reinforcing with 12" x 16" perimeter turndown and spread footings at all column lines. Concrete slab in warehouse 6" thick poured over 6-mil polyethlene vapor barrier. Concrete 3000-psi mix with fibers. Portion of slab is reinforced with #4 rebar in area shown on plans.
Brief electrical, surely more has been added to this building:
4) 200 amp. 230/120/3 disconnects
4) 200 amp breaker panels
1) 100 amp breaker panel
84) 400 watt high bay metal halide
16) 8' strip florescents
6) exit lights
6) 175 watt metal halide wall packs
10) Emergency battery packs
3) dock lights
30) 110 volt duplex receptacles
Original building offers the following:
30,000 sq. ft. (200' x 150')
2,300 sq. ft. office/bathroom space with central heat and air